120W 20A 150V Constant Power Electronic Load Programmable OEM

Product Details

Place of Origin: China

Brand Name: Topfer

Model Number: TDL-6012J

Payment & Shipping Terms

Minimum Order Quantity: one set

Price: to be discussed

Packaging Details: wooden crate

Delivery Time: 1 to 2 weeks

Payment Terms: T/T

Supply Ability: 10 sets /20 days

Get Best Price
Product Details
Highlight:

120W constant power electronic load

,

OEM constant power electronic load

,

120W ac programmable load

Power:
120W
Current:
20A
Voltage:
150V
Minimum Operating Voltage:
1V@20A
Precision:
0.03%+0.08%FS
Range:
10uS~50S
Power:
120W
Current:
20A
Voltage:
150V
Minimum Operating Voltage:
1V@20A
Precision:
0.03%+0.08%FS
Range:
10uS~50S
Product Description

120W/20A/150V electronic load, 500KHz synchronous sampling, pursuing real and fast load simulation

 

Introduction:

    The TDL-6000J series electronic load, leveraging 500KHz high-speed synchronous sampling and DSP technology, comprehensively enhances transient testing and multi-faceted intelligent analysis. It is fully integrated into the automatic testing function, making it particularly suitable for mass production and incoming inspection in the power supply and related industries. The programmable current rise rate, high-speed dynamic loading, and programmable sequence functions can also meet most research and development needs. The unique synchronous master-slave parallel timing can fulfill the simultaneous loading requirements of multiple output power supplies and the power expansion needs of single output power supplies.

 

Features:

  • Max power 300W; Max current 60A; Max voltage 500V.
  • Supports synchronous loading for 16 loads, meeting the testing needs of multiple output power supplies.
  • Supports synchronous parallel operation for 16 loads, meeting the power expansion needs of single output power supplies.
  • 500KHz synchronous sampling, with stable resolution output at 10Hz, 10uA, and 0.1mV.
  • Measurement of voltage/current ripple (Vpp/Ipp), peaks (Vp+/Ip+), and valleys (Vp-/Ip-).
  • Fastest full-scale current rise time of 10µS, programmable current rise/fall rates.
  • Four basic operating modes: constant current, constant voltage, constant power, and constant resistance.
  • Supports real LED simulation function.
  • Supports CV/CC source constant power/constant resistance, with intelligent detection and matching in constant resistance mode for CV/CC sources.
  • High-frequency dynamic loading mode (DYNA) up to 50KHz, along with voltage peak (Vp+) and valley (Vp-) measurements.
  • Supports overcurrent protection testing (OCP) and maximum power point capture (Pmax).
  • Supports load effect measurement (Load Effect).
  • High-speed dynamic frequency sweep technology (sweep).
  • Supports timing measurement (Timing).
  • Supports overvoltage protection (OVP) testing.
  • Built-in waveform generator, capable of simulating various loading waveforms in List mode.
  • Supports short circuit (Short) simulation function.
  • Supports standalone automatic testing (A-Test), all extended modes, and all test items.
  • Supports battery internal resistance and capacity testing (Battery).
  • Supports remote compensation.
  • Supports Von and Voff functions.
  • Quick access supports storage and retrieval of 20 sets of global data.
  • High-brightness, full-view angle large-screen graphic dot matrix display.
  • Overvoltage/overcurrent/overpower/overheat protection; reverse polarity protection for power supply.
  • Stepless servo, intelligent fan system.
  • Electrical isolation, external trigger input/output.
  • Electrical isolation, standard RS232 interface.
  • Supports current waveform monitoring output.
  • Standard SCPI protocol.

 

Specification sheet:

Model TDL-6012J
Rated input Power 120W
Voltage 0~15V 0~150V
Current 0~3A 0~20A
Minimum operating voltage 1V@20A
Constant Current (CC) mode Range 0~3A 0~20A
Fineness 0.05mA 0.5mA
Precision 0.03%+0.08%FS
Constant Voltage (CV) mode Range 0~15V 0~150V
Fineness 0.2mV 2mV
Precision 0.03%+0.03%FS
Constant Power (CP) mode Range 120W
Fineness 16Bits
Precision 0.1%+0.1%FS
Constant Resistance (CR) mode Range 0.05Ω~50KΩ
Fineness 16Bits
Precision (0.1+0.01R)%
Dynamic operation mode Range 10uS~50S
Fineness 2uS
Precision 1uS+20PPM
Slew rate 0.6A/mS~3A/uS
Voltage measurement Range 0~15V 0~150V
Resolution 0.1mV 1mV
Precision 0.02%+0.03%FS
Current measurement Range 0~3A 0~20A
Resolution 0.01mA 0.1mA
Precision 0.03%+0.08%FS
Ripple measurement Range 0~15V 0~150V
Bandwidth 10Hz~100kHz
Intensive reading 1mV 10mV

 

120W 20A 150V Constant Power Electronic Load Programmable OEM 0