Send Message

Dongguan Chuangrui New Energy Co., Ltd topfer99@126.com 86--13018677119

Dongguan Chuangrui New Energy Co., Ltd Company Profile
products
Home > products > Power Supply Aging > Customized Power Supply Aging Test Bench Solution 110V2A For LCU

Customized Power Supply Aging Test Bench Solution 110V2A For LCU

Product Details

Place of Origin: China

Brand Name: Topfer

Model Number: TF-LJ15048The

Payment & Shipping Terms

Minimum Order Quantity: One Set

Price: to be discussed

Packaging Details: wooden crate

Delivery Time: 5 to 6 weeks

Payment Terms: T/T

Supply Ability: 1 sets /40 days

Get Best Price
Product Details
Highlight:

Power Supply Aging Test Bench

,

LCU Power Supply Aging

,

Customized power supply test bench

Product Intputel:
77-137.5V
Product Output:
110V2A
Aging Temperaturecy:
20-70
Aging Capacity:
16PCS
Aging Time:
4Hours
Product Intputel:
77-137.5V
Product Output:
110V2A
Aging Temperaturecy:
20-70
Aging Capacity:
16PCS
Aging Time:
4Hours
Product Description

TYLCU03 - Customized Aging Test Bench Solution

 

Logic Control Unit (LCU) Aging /Temperature Impact,Voltage Fluctuation,16PCS

 

Application Range:

      Logic Control Unit (LCU)

 

Functions and Advantages:

1.Product input and output, 24-channel voltage acquisition card, acquires input voltage from DC0-150V, sends logical commands via PLC.

2.Temperature acquisition function, using a temperature acquisition module to instantly read the temperatures of the product area and load modules for control.

3.Faulty product alarm function, IO board logic judgment, if there is input but no output or no input but output, the system identifies it as a faulty product and triggers an audible and visual alarm via a buzzer.

4.Machine parameter settings, aging time, ON/OFF timing, input voltage, and load recording are saved. Upon startup, these settings can be directly retrieved without the need for reconfiguration each time.

5.Barcode Scanning Functio

6.Remote Monitoring Function

 

Specification Table:

Model TF-LJ15048T
Single Channel Power 60W/CH
Number of Load Channels 48CH
Load Voltage Range 77-137.5V
Load Current Range 0.5-20A/CH
Load Accuracy ±(1%+0.05FS)
Number of Layers in Product Area 6
Height of Layers in Product Area 170
Width of Product Area 380
Load Module Selection Electronic Load Type
Load Mode CC+CV
Temperature Control in Product Area Product Area Temperature Control: Ambient to 60°C
Trolley Structure Material Finely processed cold-rolled plate
Main Control Method Computer Monitoring Power Supply Aging Supervision Software
Input Method of Power Supply Under Test Universal Socket/Speaker Clamp/Customized by Customer
Interface Method of Power Supply Under Test Multiple specifications of adapter fixture plates to choose from/Customized by customers
Exterior Dimensions(L*W*H) 2050*900*1950/Customized by Customer

 